Berthold: GAMMAcast Radiometric Mould Level Gauge| Đầu dò mức khuôn (Model: LB6739)

Giá bán: Vui lòng gọi
Tình trạng: Mới 100%
Xuất xứ: Berthold
Mô tả:

Highest reliability Virtually unlimited measuring range Very robust Applicable for all mould types Easy calibration Minimum source activity due to high-sensitive detectors Maintenance-free Constantly high accuracy over the whole measurement range


MÔ TẢ SẢN PHẨM

The radiometric mould level measurement is maintenance-free and applicable for different mould types. Successful applications can also be found in Beam Blank and Round casters. Although working under extreme temperatures and harsh environmental conditions, the measurement has proven to be reliable for many years of operation.
System characteristics
  • Highest reliability
  • Virtually unlimited measuring range
  • Very robust
  • Applicable for all mould types
  • Easy calibration
  • Minimum source activity due to high-sensitive detectors
  • Maintenance-free
  • Constantly high accuracy over the whole measurement range
Measuring Principle
Gamma radiation is attenuated as it passes through the mould. This attenuation is measured by a detector. The extent to which the radiation is attenuated depends on the mould level. The higher the level of molten metal in the mould, the less radiation will reach the detector. In this manner, the mould level can be reliably monitored - irrespective of dust, temperature and vibrations.
GAMMAcast Detectors
GAMMAcast detectors are characterized by their excellent sensitivity for gamma radiation, leading to a significant reduction of source size. The new robust detector design and the PlugProtect cable connection ensure highest mechanical stability and an extended lifetime.
Activity Optimized Source (AOS)
The Activity Optimized Source allows for an enhanced measuring performance. By modifying the activity distribution along the source the accuracy around the set point can be significantly improved.
Alternatively, when the accuracy is to remain unchanged, the source activity can be reduced by several factors. This allows for the use of smaller shieldings, which is a major benefit in terms of space and costs. In individual cases it is also possible to work with the significantly more cost-efficient lead as shielding material.

 

RESOURCE & DOWNLOAD

 

Brochure
 Flyer AOSActivity Optimized Source EN PDF 500.37 KB
 Mold Level Measurement Brochure EN PDF 1.16 MB
Operation Manual
 GAMMAcast detectors EN PDF 4.31 MB
 LB 452 castXpert EN PDF 5.47 MB
Software Tool
 GAMMAcast Software Update, Version 1.2.5 EN ZIP 195.71 KB
Technical Information
 LB 452 castXpert and GAMMAcast detectors EN PDF 2.39 MB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


BERTHOLD LB 6739

 

 

 

Vui lòng liên hệ:

 

 

CÔNG TY TNHH GIẢI PHÁP VÀ CÔNG NGHỆ ĐO LƯỜNG INO

Địa chỉ: 98/31B, Đường Linh Đông, Phường Linh Đông, Quận Thủ Đức, TP Hồ Chí Minh, Việt Nam 

Tel:  (+84)8.37200.184 |  Fax: (+84)8.37200.197  |  Email: info@ino.com.vn

Hot line: 0939.021.319Website: www.ino.com.vn

để được hỗ trợ !